-Recent versions of the software stack (> 09/2018) support updating the minimum battery voltage from the Plan 3.0 GUI. Rather than using a fixed value, FlexSEA-Regulate and FlexSEA-Manage will both pull from their non-volatile memory. If a valid value has been programmed they will use it. If not they will send the default value. To change the cutoff voltage, simply open the Calibration Tools. You can read the value, and you can write a new one. Always power-cycle the system after doing so.+Recent versions of the software stack (> 09/2018) support updating the minimum battery voltage from the Plan 3.0 GUI. Rather than using a fixed value, FlexSEA-Regulate and FlexSEA-Manage will both pull from their non-volatile memory. If a valid value has been programmed they will use it. If not they will send the default value. To change the cutoff voltage, simply open the Calibration Tools. You can read the value, and you can write a new one. Always power-cycle the system ​**twice** ​after doing so to make sure that the non-volatile values get used (some of that code is only called at boot).
  
 +{{ :uvlo.gif |}}
 +
 +Older version:
 {{ :​uvlocal.png?​400 |}} {{ :​uvlocal.png?​400 |}}